23
MAINTENANCE
Proper routine maintenance of the generator will help prolong the life of the machine. Please perform maintenance
checks and operations according to the schedule in Table 4.
CAUTION! Never perform maintenance operations while the generator is running. Before maintaining or
servicing the generator, turn OFF the generator, disconnect all devices and allow the generator to cool down.
If there are any questions about the maintenance procedures listed in this manual, please call 1-(800) 232-1195 M-F
8-5 CST or email techsupport@wenproducts.com.
Recommended
Maintenance Schedule
Every 8
Hours or
Daily
Every 25
Hours
Every 3
Months or
50 Hours
Every 6
Months or
100 Hours
Before
Storage
As
Necessary
Engine Oil
Check Level x
Replace x* x
Air Filter
Check x*
Clean x*
Spark Plug
Check/Clean/
Regap
x
Change x x
Fuel
Check Level x
Drain x x
Carburetor Drain x x
Spark
Arrestor
Check/Clean x
Table 4 - Recommended Maintenance Schedule* Clean/change more often under dusty conditions
or operating under heavy load.
IMPORTANT GENERATOR MAINTENANCE TIPS:
Drain your carburetor after each use and before storage to prevent it from clogging.
Do not store the generator with fuel inside the tank for more than 2 months - the fuel will go bad.
Run the generator for at least 15 minutes every month to maximize its lifespan.
CLEANING THE GENERATOR
Keep the generator clean to prevent improper operation or machine damage from dirt and debris. Inspect all venti-
lation openings on the generator. These openings must be kept clean and unobstructed. If the generator becomes
dirty, use a damp cloth to wipe exterior surfaces. Use a soft bristle brush to loosen dirt and oil and use a vacuum to
pick up loose dirt. Use low pressure air (not to exceed 25 PSI) to blow away dirt.
CAUTION! Never clean the generator when it is running! Never clean with a bucket of water or a hose. Water
can get inside the working parts of the generator and cause corrosion or a short circuit.
NOTE: Failure to properly maintain the generator will void the warranty.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wen 56235i and is the answer not in the manual?

Wen 56235i Specifications

General IconGeneral
ModelWen 56235i
CategoryPortable Generator
Running Watts1900W
Starting Watts2350W
Engine79.7cc 4-stroke OHV
Fuel TypeGasoline
Tank Capacity1 Gallon
Noise Level51 dB
InverterYes
Starting SystemRecoil
Rated Voltage120V
Rated Frequency60 Hz
Max Output2350W
Weight39 pounds
Outlets1x 12V DC
DC Output12V, 8.3A
Run Time at 50% Load6 hours

Related product manuals