Storage
The materials used in the manufacture of the Showmobile are generally waterproof� However, under prolonged
exposure to the elements, some of these materials may eventually show signs of decline� Therefore, Wenger
strongly encourages you to:
• Store the unit inside a building when not in use�
• Cover any components which are left outside overnight, for long periods of time, or during inclement weather�
Regular storage will protect your investment and add years to the life of the Showmobile�
Repair Parts
When you contact Wenger for any repair parts for the Showmobile, be sure you know the Serial Number of the
unit (refer to the decal inside the control compartment door)�
Lubrication
All moving parts of the Showmobile should be lubricated about twice a year� In seasonal climates, these
occasions will normally be in the spring when the Showmobile is rst put into use, and again when it is stored for
the winter�
Locks
Protect all locks, locking mechanisms, keyways, and hinges with a spray-type lubricant such as WD-40, to
prevent sticking and corrosion�
Roof/Canopy Pivot Bearings
Once a year, lubricate the bearings on the roof/canopy
pivot points (26 grease ttings total) with an all-purpose
grease�
Battery
Once a month, check the 12-volt battery (located in the
front road side corner of the Showmobile):
1. Remove the battery caps and check the uid level.
2� Check that the power and ground wires are securely
attached to the battery posts�
Before using the Showmobile, charge the battery for
24 hours to assure that adequate power will be available
at the site�
Battery Charger
The Showmobile is equipped with a battery charger/maintainer
designed to be plugged in continuously when power is available
to keep the battery charged and in peak condition�
Refer to the original Battery Charger’s Instructions received
with the battery charger for more information�
Hydraulic Fluid
Wenger recommends checking the uid level after each
10-12 uses of the roof/canopy/oor lift system.
To add uid to the hydraulic reservoir (below the stage deck),
remove the ller cap. If uid is needed, use only an approved
Dexron IIe automatic transmission uid. Never mix with other uids,
as the hydraulic components will be damaged�
28
Maintenance
Pivot Point
Grease Fittings
Risk of explosion and personal
injury see "Safety Precautions".
!
WARNING
Battery