WerkMaster machines come in a variety of voltage and phase configurations.
The Raptor XTi is typically configured to operate on 208230V three-phase
power. It is capable of operating on single-phase 208230V power with the use
of the adapter cord (included), as well as 110V using a Quick 220 Adapter.
Pigtails are plug ends with unfinished bare wire on one end for hooking up to
panels. Pigtails are used when connectivity is unknown, when connecting to the
power grid of an unfinished building that has no power receptacles, or when
operating certain generators. Many pigtails are available or can be made up by
an electrician.
When using the Raptor XTi in a residential environment, source power may be
hard to find. The use of stove and dryer adapter cords make single-phase source
power easier to connect to. The dryer adapter cord is outfitted with a 30A 250V
single-phase twist-lock cord end. The stove adapter cord is outfitted with a 40A
250V single-phase twist lock cord end. The single-phase to three-phase adapter
is used to connect the dryer/stove adapter cord to the Raptor XTi only.
When using the Raptor XTi in a residential environment, source power may be
hard to find. Plug two 110V cords from the Quick 220 into the 110V wall outlet on
two (2) separate circuits. Plug the WerkMaster machine into the Quick 220
adapter.
NOTE: A 20 Amp to 30 Amp single-phase to three-phase adapter (optional)
would be required.
!
The following table lists the minimum requirements for power cords.
!
!
!
The following table lists the minimum requirements for generators'!
!
!
MODEL
MINIMUM REQUIREMENT
(KW)
Viper XTi
5
Raptor XTi
6
!
!
!
!
!
Exercise extreme caution at all times when working with electrical power.
WerkMaster strongly recommends that only certified electricians be permitted to
work with electrical power sources within customers’ facility or on their job site.
Single-Phase to Three-Phase
Adapter Cord
Pigtails
Stove and Dryer
Adapter Plugs
Quick 220 Adapter
Power Cord
Minimum Requirements
MODEL
DISTANCE
MINIMUM REQUIREMENT
Viper XTi
Raptor XTi
Up to 300 ft
Up to 300 ft
Single-phase minimum gauge of 10/3
Single-phase minimum gauge of 10/3
Three-phase minimum gauge of 10/4
Generator
Minimum Requirements
! ! ! !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! !E&%+F+A!