PRO-FLO
TAILGATE SPREADER
Owners Manual
CAUTION
Read this manual before installing or operating
the spreader.
This manual supersedes all editions with an earlier date.
This manual is for WESTERN
®
PRO-FLO
Spreaders with serial numbers
(115297 - )
®

Questions and Answers

  • J
    James LewisAug 16, 2025
    Why does my Western PRO-FLO spinner not turn even though the motor is running?
    • D
      Danielle MooreAug 16, 2025
      If the motor of your Western Spreader is running but the spinner isn't turning, consider these possibilities: * There might be an obstruction preventing rotation. Clear any obstructions. * The drive belt could be loose or damaged. Adjust the tension or replace the belt if it's worn or damaged. * The motor pulley might not be secured to the motor shaft. Tighten the pulley set screw, or replace the pulley if it's damaged. * The spinner pulley may not be secured to the spinner shaft. Replace the cap screw and nut if they're missing or damaged. Replace the pulley if it's damaged. * The spinner shaft bearings could be dry or seized. Grease or replace the bearings.
  • S
    Sharon MartinezAug 25, 2025
    What causes ice control material not flowing in Western PRO-FLO Spreader?
    • E
      enelsonAug 25, 2025
      If ice control material isn't flowing in your Western Spreader, even though the spinner is turning, it may be due to bridging of material or an obstruction in the hopper. Unplug the spreader harness and tag out if required. Check the hopper for material and free any bridged material or obstruction.
  • J
    Joseph RosarioAug 27, 2025
    Why speed control dial on Western Spreader does not change motor speed?
    • D
      Daniel MeadowsAug 28, 2025
      If the speed control dial on your Variable Speed (PWM) cab control isn't changing the motor speed, it could be due to: 1. A malfunctioning cab control. Replace the cab control. 2. Incorrectly hooked up red and white connectors. Reconnect them so that red matches red and white matches white.
  • N
    Nathaniel JacksonAug 31, 2025
    How to fix spread pattern on Western PRO-FLO Spreader?
    • C
      Christopher ShermanAug 31, 2025
      If the spread pattern is not optimum on your Western Spreader, it could be because the deflector is out of adjustment. Unplug the spreader harness and tag out, if required. Change the deflector adjustment to suit desired pattern.
  • P
    parrishalexanderSep 4, 2025
    What to do if my Western PRO-FLO spinner does not turn?
    • T
      Terri WilcoxSep 4, 2025
      If the Western Spreader spinner shaft won't turn manually, clear any obstructions from the spinner or shaft and lubricate the bearings. If the shaft turns freely and the condition persists, the issue lies within the motor or the cab control. To address an overload condition, reset the cab control by turning the power switch off, then depress the START/BLAST switch. If this doesn't resolve the issue, turn off the power at the cab control, disconnect the electrical plug at the spreader.
  • N
    Nicole LeSep 8, 2025
    How to check the power on a Western PRO-FLO if the spinner does not turn?
    • M
      mallory38Sep 8, 2025
      First, ensure the ignition switch is on and the cab control is also turned on. Then, check for power reaching the cab control of your Western Spreader. This could resolve the issue of the spinner not turning.
  • J
    Joseph SmithNov 12, 2025
    What to do if Western PRO-FLO Spreader does not operate but the indicator light is on?
    • T
      Taylor MooreNov 12, 2025
      If your Western Spreader isn't operating, but the indicator light is illuminated, there are several potential causes: 1. The over-current protection might be activated due to an overloaded condition (Variable Speed Control only). In this case, turn the power OFF to reset the cab control, then depress the START/BLAST switch to resume operation. 2. There may be damage or an open circuit in the wire harness between the cab control and spreader. Inspect plug connections at the cab control and spreader. Also, check wire connections at the spreader motor and vehicle battery. Disconnect the motor leads, turn the control on, and set the cab control to maximum on variable speed controls to check for voltage at the motor leads. Repair or replace any damaged wires and connectors. Check the 30 Amp ...
  • J
    Janet JohnsonNov 19, 2025
    How to troubleshoot Western PRO-FLO Spreader with no power to cab control?
    • D
      Dana McdanielNov 19, 2025
      If there is no power to the cab control of your Western Spreader (with ignition and control switches ON, and no illumination of indicator lights), consider the following troubleshooting steps: 1. Check the control connector plug at the cab control to ensure it is not loose. 2. Inspect the battery lead in-line fuse. If it's blown, change the fuse (use a 6 amp fuse for a 4-pin harness or a 10 amp fuse for a 3-pin harness) and inspect for short circuits. Also, check the power supply for 12V DC. 3. Check the battery connection for any issues. Look for a low battery and clean or replace the ring terminal, coating it with dielectric grease. 4. Inspect the battery wiring harness for damage. Repair or replace any damaged wires or the harness as needed. 5. If you have an ON/OFF Control, check...

Summary

SAFETY INFORMATION

LOADING

MOUNTING THE SPREADER

In-Bed Mount

Step-by-step guide for mounting the spreader in the truck bed.

Under-Frame Mount

Instructions for mounting the spreader using an under-frame hitch system.

OPERATING THE SPREADER

Driving and Spreading on Snow and Ice

Tips for safe driving and operating the spreader in winter conditions.

Variable Speed (PWM) Control

Explanation of the Variable Speed (PWM) control for spinner speed adjustment.

ON;OFF Control

Description of the ON/OFF control switch for the spinner.

Starting and Stopping the Motor

Procedures for starting and stopping the spreader motor.

REMOVING THE SPREADER

RECEIVER HITCH

Towing System Safety

Important safety warnings and precautions for towing systems.

Trailer Sway Management

Understanding, assessing, and controlling excessive trailer sway conditions.

MAINTENANCE

TROUBLESHOOTING GUIDE

VARIABLE SPEED (PWM) CONTROL TROUBLE SHOOTING GUIDE

Troubleshooting steps for issues with the variable speed control system.

Western PRO-FLO Specifications

General IconGeneral
BrandWestern
ModelPRO-FLO
CategorySpreader
LanguageEnglish