For Service Technician Use Only
DIAGNOSTICS
Multi-Door Freestanding Refrigerator
n
2-3
Diagnostics Mode

 

Compressor
BTUH Variable VEGDGH
Wa 60 Hz / 98 W
Current Lock rotor 3.3 A ± 15%
Current Full load 3.3 A ± 15%
Resistance Run windings 6.4 ± 15%
Resistance Start windings 6.4 ± 8%@77°F
Inverter 3.6 VDC, red/white = 120 VAC
Electric damper control
Maximum closing me 16 seconds
Temperature Rang -11°F - 110°F
RPM 3
Condenser motor
Rotaon (facing end opposite sha) Clockwise
RPM 940
Wa 3.9 W± 15% @115 VAC
NOTE: Fan blade must be fully seated on sha to achieve proper airow.
Refrigerator Evaporator fan motor
Rotaon (facing end opposite sha) Clockwise
RPM 940
Wa 2.5± 15% W @12.7 VDC
Freezer Evaporator fan motor
Rotaon (facing end opposite sha) Clockwise
RPM 2700
Wa 5.0± 15% W @12.7 VDC
NOTE: Fan blade must be fully seated on sha to achieve proper airow.
Freezer Evaporator Heater
Volt 115VAC
Wa 435 ± 5% W
Resistance 30.4± 5%

Control Board
Volt
See control board secon for diagnoscs
120 VAC, 60HZ
Thermistor
Temperature Resistance
77°F 2700 ± 5.0%
36°F 7964 ± 1.0%
0°F 23,345 ± 2.0%
Light switch
Type SPDT NO/NC
Volt 125/250 VAC
Current 8/4 A

Dual Water Valve Was Green side 10 W
Red side 35 W
Isolaon Valve Was 20 W (Green)
Ice Box Fan
Rotaon (facing end opposite sha) Clockwise
RPM 3500
Wa 3.8 W ± 15% @ 12.7 VDC