Kunststoffschweißtechnik
Starting and operating Chapter 5
18.07.2013 Working Instructions WIDOS ESI 4000 Page 24 of 37
5.7. Error messages
In case that the following happens during working with the ESI 4000:
The rules according to DVS have not been observed,
The socket shows a defect,
The plug was unintentionally separated from the socket,
Certain measuring facilities do not work, one of the following error messages appears on
the display:
W Error welding time
U Error voltage
I Error socket current
c Error cooling down
T Error heat sink too hot
S Error current failure
B user’s abort
All error messages are logged.
5.8. Enter parameters
Display:
2nd line:
WIDOS ESI 4000
10.10.2011 10:10
Basic menu
Current date and time
Simultaneously press <+> and <-> - buttons
Display:
2nd line:
last project
WIDOS
-------------------
Last project is indicated,
Select one of the last 4 projects by <+> or <->
Confirm by <Start>
Display:
2nd line:
Name of project
WIDOS
-------------------
Current project name is indicated
<+ / -> - buttons, change project name if necessary (then the name of the
last project is overwritten)
Confirm by <Start>
or: keep <Start> pressed to go to the end of the figures
or: read in barcode of a project name with the barcode reading pen (barcode
may be created with WICON2000)
Display:
2nd line:
Number of joint
0000
Current joint number of last project