Kunststoffschweißtechnik
Starting and operating Chapter 5
18.07.2013 Working Instructions WIDOS ESI 4000 Page 29 of 37
5.12. Traceability–how to activate information and pipe length
Display:
2nd line:
WIDOS ESI 4000
10.10.2011 10:10
Basic menu
Current date and time
Simultaneously press <- and Start> for next menu item
Display:
2nd line:
WIDOS ESI 4000
Please authorize
Only possible with general authorization card
Authorize by bar code reading pen and general authorization card
Display:
2nd line:
WIDOS ESI 4000
10
.10.2011 10:10
Current date and time is indicated
Press <Start>
Display:
2nd line:
Authorization
y
es
Press <Start>
Display:
2nd line:
Name of project
WIDOS
--------------------
Current project name is indicated
Confirm by <Start>
Display:
2nd line:
Traceability
n
o
You may select traceability yes / no
Select “YES” with <+> if you require traceability
Only appears if traceability has been selected with yes.
Display:
2nd line:
pipe length
y
es
You may select pipe length yes / no
Select pipe length yes by <+>