3. Specications
Specications Models T32.xS, T32.xR
Permissible ambient temperature
range
{-50}-40...+85°C
Climate class per IEC 654-1: 1993 Cx(-40...+85°C,5...95%relativeair
humidity)
Maximum permissible humidity
ModelT32.1S
perIEC60068-2-38:1974
ModelT32.3S
perIEC60068-2-30:2005
Testmax.temperaturevariation65°C
and-10°C,relativehumidity93%±3%
Testmax.temperature55°C,relative
humidity95%
Vibration per IEC 60068-2-6: 2007
TestFc:10...2000Hz;10g,
Amplitude0.75mm
Shock per IEC 68-2-27: 1987 TestEa:AccelerationTypeI30gand
TypeII100g
Salt mist per IEC 60068-2-52 Severitylevel1
Free fall drop per IEC 68-2-52: 1996 Dropheight1500mm
Electromagnetic compatibility
(EMC)
EMCdirective2004/108/EC,EN61326
Emission(Group1,ClassB)and
immunity(industrialapplication)
{}Itemsincurvedbracketsareoptionsforadditionalprice,notforrailmountingversionT32.3S
ThemodelsT32.1RandT32.3Rtemperaturetransmitters
areavailableonrequest.TheCEdeclarationofconformity
(ATEX/EMC)isvalidwithoutrestrictionsforT32.1Rand
T32.3R(seeAppendix2"ECDeclarationofconformity").
ForfurtherspecicationsseeWIKAdatasheetTE32.04andthe
orderdocumentation.
Forfurtherimportantsafetyinstructionsforoperationin
hazardousareasseechapter10"Notesformountingand
operatinginhazardousareas".