OWNER’S MANUAL
INSTALLATION INSTRUCTION
DIRECT-VENT
WALL FURNACE
MODELS:
1403822; 1413822; 1433822; 1453822;
2203822; 2213822; 2233822; 2253822;
3003822; 3013822; 3033822; 3053822
NATURAL GAS ONLY
MODELS:
1403821; 1413821; 1433821; 1453821;
2203821; 2213821; 2233821; 2253821;
3003821; 3013821; 3033821; 3053821
PROPANE GAS ONLY
SAVE THIS MANUAL FOR FUTURE REFERENCE.
14,000 BTU/hr. 22,000 & 30,000 BTU/hr.
READ THIS OWNER’S MANUAL CAREFULLY BEFORE YOU
INSTALL YOUR NEW WILLIAMS WALL FURNACE.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS:
Open all windows
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone or cell phone in your
building.
Extinguish any open flame.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
WARNING: If the information in these
instructions is not followed exactly, a fire or
explosion may result causing property damage,
personal injury or loss of life.
250 WEST LAUREL STREET, COLTON, CA 92324 U.S.A.
WARNING: Improper installation, adjustment, alteration,
service or maintenance can cause injury or property damage.
Refer to this manual for proper installation. For assistance or
for additional information consult a qualified installer, service
agency or the gas supplier.
WARNING: This product can expose you to chemicals
including epichiorohydrin which is known to the State of
California to cause cancer and birth defects and/or other
reproductive harm. For more information go to
www.p65warnings.ca.gov.

Questions and Answers

  • M
    Mackenzie BarrettSep 12, 2025
    How do I fix a noisy blower in my Williams 1403821 Furnace?
    • J
      Joseph CarpenterSep 12, 2025
      A noisy blower can be caused by several issues. If the housing is rattling, try tightening the blower screws. A dirty blower wheel can also cause noise, so clean it thoroughly. If the blower wheel is bent, attempt to straighten it or replace it if necessary.
  • D
    Dylan JohnstonAug 25, 2025
    Why Williams 1403821 pilot will not stay lit?
    • K
      Kelsey AndrewsAug 25, 2025
      If the pilot light on your Williams Furnace won't stay lit after you've followed the lighting instructions, there are several potential causes. First, the generator may not be producing enough millivolts because the pilot flame isn't properly hitting the generator, or the generator isn't fully inserted. Also, ensure the pilot lighting door is tightly closed. The generator itself could be defective, or the connections at the gas valve might be loose or dirty. Another possibility is a grounded thermostat lead wire. Finally, the gas valve itself could be defective and require replacement after the other possibilities have been eliminated.
  • T
    Timothy EdwardsAug 27, 2025
    How to fix a pilot outage problem in Williams Furnace?
    • G
      Gary ParkerAug 27, 2025
      If you're experiencing pilot outages, first adjust the pilot flame, as it may be too low or blowing. Inspect the vent tube and air inlet tube. Ensure the pilot lighting door is closed properly. Also, the pilot orifice or aerating hole may be plugged; check for obstructions like spiders or webs. Additionally, check the control and pilot observation doors for broken or missing gaskets; clean and replace them if necessary.
  • M
    Michael BallAug 27, 2025
    What to do if the blower on my Williams Furnace doesn't run?
    • M
      Michael WarrenAug 28, 2025
      If the blower isn't running, first ensure the fan switch is properly set to the desired fan speed. Also, check the bearings and add oil as instructed in the blower instructions.
  • V
    Vanessa RichardsonAug 29, 2025
    What to do if Williams 1403821 burner comes on then goes off?
    • B
      Bryan BrewerAug 29, 2025
      If your Williams Furnace burner comes on but then shuts off for no apparent reason, check the vent tube and the air inlet tube to ensure they are properly installed according to the installation instructions. Make sure the joints are tight and both tubes are correctly in place, using only the provided tubes and not extending them beyond their original length. The furnace might also be overrated, so check for high pressure at the valve and consult the rating plate for the specified minimum/maximum supply pressure. Also, check the burner orifice.
  • C
    Cheryl CostaAug 31, 2025
    Why my Williams 1403821 operates but turns off before reaching room temperature?
    • A
      amyjohnsonAug 31, 2025
      If your Williams Furnace operates but turns off before the room reaches the set temperature, the thermostat location could be the issue. Ensure it's not in the path of warm air from the furnace, near a lamp, or above a TV or stereo. Alternatively, the thermostat itself may be defective, so check its calibration or consider replacing it.
  • K
    Kevin MccoyNov 20, 2025
    Why won't the pilot light stay lit on my Williams Furnace?
    • R
      Rebekah CollinsNov 20, 2025
      Several factors can cause the pilot light to go out. First, ensure the pilot flame fully impinges on the generator and that the generator is completely inserted in its bracket, and the pilot lighting door is tightly closed, as an insufficient generator output can cause this. Also, the generator itself may be defective; test it with a millivolt meter, ensuring a reading of 140 millivolts or higher at the valve terminals with the pilot burning and thermostat contacts closed. Loose or dirty connections at the gas valve can also be the culprit, so clean and tighten these. A grounded thermostat lead wire can also cause this issue; remove the thermostat lead wires to check for a ground within the thermostat wiring circuit, potentially caused by contact with the furnace, gas supply, or fasteners....
  • H
    hollymillerSep 13, 2025
    What to do if Williams 1403821 Furnace pilot is burning but no gas to the main burner?
    • J
      Jill MullinsSep 13, 2025
      If the pilot light is burning in your Williams Furnace, but no gas is reaching the main burner, first ensure that the valve is turned to the 'ON' position after lighting the pilot and that the thermostat is set to a position calling for heat. Check for a plugged burner orifice and clean or replace it if necessary. Inspect the thermostat wires for improper wiring or breaks, and check the connections at the valve terminals. You can also temporarily bypass the thermostat by using a jumper across the thermostat terminals on the valve. If the valve operates, focus on checking the thermostat wires. The pilot generator might not be generating enough millivolts to open the valve. Finally, the valve itself could be defective, requiring replacement after verifying the other potential causes.
  • F
    Francisco RiveraSep 10, 2025
    Why does my Williams 1403821 Furnace burner turn on and off?
    • E
      Elizabeth CampbellSep 10, 2025
      If the burner turns on but then shuts off unexpectedly, check the vent tube and the air inlet tube to ensure they are properly installed according to the installation instructions. Make sure the joints are tight, both tubes are in place, and only the furnished tubes are used, without extending them beyond their original length. Also, the furnace may be overrated, so check for high pressure at the valve and verify the burner orifice.
  • J
    James MirandaSep 7, 2025
    Why is my Williams Furnace not producing enough heat?
    • H
      holmestimothySep 7, 2025
      If your furnace isn't producing enough heat, it might be too small for the space you're trying to heat; check the heat calculations to confirm. Also, the furnace may not be burning at its full rate. Check for low gas pressure and inspect the burner orifice for any obstructions.

Summary

Installation

Locating Wall Furnace

Finding the correct placement for the furnace on an outside wall.

Interior Clearances

Ensuring required space around the furnace for safety and operation.

Wall Opening and Vent Preparation

Creating wall openings for vent, gas, and electrical supply.

Furnace and Cabinet Mounting

Installing spacer plate, furnace, vent cap, and cabinet.

Thermostat Installation

Installing the thermostat according to wall mounting guidelines.

Gas Supply and Piping

Connecting gas lines, checking orifices, and leak testing.

Operating Your Furnace

Lighting the Pilot

Step-by-step guide for igniting the pilot light.

Operating Instructions

Sequence of operations for the furnace.

To Turn Off Gas To Appliance

Procedure for shutting off gas supply to the unit.

Start-Up Procedure

Initial steps for starting the furnace after installation.

Gas Pressure and Input Checks

Verifying gas pressure and input rate against specifications.

How to Care for Your Furnace

Abnormal Appearance

Identifying and understanding unusual flame behavior.

Annual Upkeep and Cleaning

Recommended maintenance tasks for optimal performance.

Pilot Burner Adjustment

Adjusting the pilot flame for proper operation.

Blower Accessory 2302 and 2303

Mounting and Field Wiring

Instructions for installing and wiring the blower accessory.

Blower Operation Modes

Explains automatic and continuous fan operation.

Replacement Parts List

Blower Accessory Parts

Parts list for Blower Accessory 2302 and 2303.

14038 Series Furnace Parts

Replacement parts for 14038 series furnaces.

22038;30038 Series Furnace Parts

Replacement parts for 22038, 30038 series furnaces.

Burner and Valve Components

Replacement parts for burners, gas valves, and electrodes.

Hints and Information

Service Hints

General advice for furnace service and maintenance.

Gas Leak Emergency Procedure

Steps to take if you smell gas.

Ordering Replacement Parts

Information required when ordering new parts.

Williams 1403821 Specifications

General IconGeneral
BrandWilliams
Model1403821
CategoryFurnace
LanguageEnglish

Related product manuals