5.2 Technical data
5.3 Scope of delivery
• Lifting system
• Operating manual
For HiDrainlift3-24:
clamp 20x32 (x2), clamp 25x40 (x1), inlet lateral plug (x2), plug (x1),
outlet elbow (x1).
For HiDrainlift 3-35 and HiDrainlift 3-37:
outlet elbow (x1), 2-outlet bushing (x1), clamp 32x55 (x8), clamp 25x40 (x1),
inlet bush (x3), inlet lateral plug (x2), screw (x2), fixation strip (x2).
5.4 Description
HiDrainlift 3-24 (Fig. 1)
1 - Elbow
2 - inlet lateral plug (x2)
3 - Plugs
4 - Clamps (2 x 20x32; 1 x 20x40)
HiDrainlift 3-35 and HiDrainlift 3-37 (Fig. 2)
1 - inlet bush (x3)
2 - Elbow
3 - 2-outlet bushing
4 - inlet lateral plug (x2)
5 - Fixation strip (x2)
6 - Screw (x2)
7 - Screw clamp (x2 for each part number)
24
English
09/2014
Hydraulic data HiDrainlift 3-24 HiDrainlift 3-35 HiDrainlift 3-37
Maximum delivery head 4 m 5 m 7 m
Maximum Horizontal
Delivery
40 m 50 m 70 m
Maximum altitude 1000 m 1000 m 1000 m
DN of suction connection DN40 DN40 DN40
DN of pressure connection DN32 DN32 DN32
Temperature range
Fluid temperature range +5°C à +35°C
+5°C à +60°C
(5 min. max.)
+5°C à +75°C
(5 min. max.)
Ambient temperature Max. +40°C Max. +40°C Max. +40°C
Electrical data
Motor protection rating IP 44 IP 44 IP 44
Insulation class Class I Class I Class I
Frequency 50 Hz 50 Hz 50 Hz
Voltage 220/240 V 220/240 V 220/240 V
Rated current 1.22 A 1.7 A 2 A