EasyManua.ls Logo

Wilo HiDrainlift 3 Series - Technical Data; Scope of Delivery; Product Description Details

Wilo HiDrainlift 3 Series
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.2 Technical data
5.3 Scope of delivery
Lifting system
Operating manual
For HiDrainlift3-24:
clamp 20x32 (x2), clamp 25x40 (x1), inlet lateral plug (x2), plug (x1),
outlet elbow (x1).
For HiDrainlift 3-35 and HiDrainlift 3-37:
outlet elbow (x1), 2-outlet bushing (x1), clamp 32x55 (x8), clamp 25x40 (x1),
inlet bush (x3), inlet lateral plug (x2), screw (x2), fixation strip (x2).
5.4 Description
HiDrainlift 3-24 (Fig. 1)
1 - Elbow
2 - inlet lateral plug (x2)
3 - Plugs
4 - Clamps (2 x 20x32; 1 x 20x40)
HiDrainlift 3-35 and HiDrainlift 3-37 (Fig. 2)
1 - inlet bush (x3)
2 - Elbow
3 - 2-outlet bushing
4 - inlet lateral plug (x2)
5 - Fixation strip (x2)
6 - Screw (x2)
7 - Screw clamp (x2 for each part number)
24
English
09/2014
Hydraulic data HiDrainlift 3-24 HiDrainlift 3-35 HiDrainlift 3-37
Maximum delivery head 4 m 5 m 7 m
Maximum Horizontal
Delivery
40 m 50 m 70 m
Maximum altitude 1000 m 1000 m 1000 m
DN of suction connection DN40 DN40 DN40
DN of pressure connection DN32 DN32 DN32
Temperature range
Fluid temperature range +5°C à +35°C
+5°C à +60°C
(5 min. max.)
+5°C à +75°C
(5 min. max.)
Ambient temperature Max. +40°C Max. +40°C Max. +40°C
Electrical data
Motor protection rating IP 44 IP 44 IP 44
Insulation class Class I Class I Class I
Frequency 50 Hz 50 Hz 50 Hz
Voltage 220/240 V 220/240 V 220/240 V
Rated current 1.22 A 1.7 A 2 A