10 Faults, causes and remedies
WARNING! Risk of electric shock!
Before any work on the system, DE-ENERGISE the unit by disconnecting
the electrical supply to the system, and prevent unauthorised restarting.
If you cannot remedy the fault, please contact Wilo customer service.
28
English
Faults Causes Remedies
The motor will not start Device is not plugged in Plug in the device
Faulty power supply Check the power supply
Problem with motor or con-
trol system
Contact an approved repair tech-
nician
The device keeps stopping
and starting
The connected sanitary
devices are leaking
Check the upstream installations
The non-return valve is
leaking
Clean or replace the non-return
valve.
The motor is running cor-
rectly but does not stop
or runs for a very long
time
The height or length of the
drain is too great (friction
loss)
Review the installation
Hydraulic problem (clogging) Contact an approved repair tech-
nician
The device has stopped The device was running for
too long (high temperature
cut-out)
Wait for reset, then contact an
approved repair technician if
necessary
Turbid water flowing
back into the shower
(device with lateral inlets)
Shower connected too low
relative to the comminutor
Review the installation
Flaps on lateral inlets clogged Clean the flaps, then contact
an approved repair technician if
necessary
09/2014