Exchange of mechanical seal, extended shaft version (Fig. 2)
Removal:
Switch off power supply to pump motor and secure against
unauthorized switching on.
Close isolating valves at both pump ports,
Remove terminal wiring, if cable too short,
Undo motor flange nuts (Item 11) and remove motor with im-
peller and rotating seal parts from motor housing,
Remove circlip (Item 7) from shaft end,
Remove impeller (Item 2) from shaft,
Remove distance ring (Item 6) from shaft,
Remove rotating seal parts (Item 5)from shaft,
Remove stationary seal ring from its seat in the motor flange
and thoroughly clean seat face,
Thoroughly clean part of shaft.
Re-Assembly:
Refit new stationary seal ring into motor flange,
Refit new rotating seal parts (Item 5) onto shaft,
Refit distance ring (Item 6) onto shaft,
Refit impeller (Item 2) to shaft end,
Fit new circlip (Item 7) to shaft end,
Fit new O-ring gasket (Item 8),
Refit motor complete with impeller and mechanical seal onto
pump housing and secure with flange bolts (Item 11),
Rewire power leads to motor terminals,
Open isolating valves at both pump ports,
Restore power supply,
Repeat measures as for commissioning (Chapter 6).