Faults, causes and remedies en
Installation and operating instructions Wilo-EMU FA + FK 17.1, FK 202, FK 34, FK 42 41
WARNING
Sharp edges on the impeller and suction port
Sharp edges can form on the impeller and suction port. There is danger of limbs be-
ing cut-off! Protective gloves must be worn to protect from cuts.
Fault: Pump is not starting
1. Electricity supply interrupted or short-circuit/earth connection in the cable or mo-
tor winding.
Have the connection and motor checked by a qualified electrician and replace
if necessary.
2. Tripping of fuses, of the motor protection switch or the monitoring equipment
Have the connection and the monitoring equipment checked by a qualified
electrician and change it if necessary.
Have the motor protection switches and fuses installed and adjusted accord-
ing to the technical specifications by a qualified electrician and reset monitor-
ing equipment.
Check the impeller to make sure that it runs smoothly, clean the hydraulics if
necessary.
3. The sealing chamber control (optional) has interrupted the electric circuit (connec-
tion-related)
See “Fault: Mechanical seal leakage, sealing chamber control reports a fault
and switches the pump off”.
Fault: Pump starts up, motor protection trips after short period
1. Motor protection switch set incorrectly.
Have the adjustment of the trigger checked and corrected by a qualified elec-
trician.
2. Increased power consumption due to major voltage drop.
Have the voltage of individual phases checked by a qualified electrician. Con-
tact the electricity distribution network.
3. There are only two phases at the connection.
Have the connection checked and corrected by a qualified electrician.
4. Excessive differences in voltage between the phases.
Have the voltage of individual phases checked by a qualified electrician. Con-
tact the electricity distribution network.
5. Incorrect direction of rotation.
Have the connection corrected by a qualified electrician.
6. Increased power consumption through jammed hydraulics.
Clean the hydraulics and check the inlet.
7. The density of the fluid is too high.
Contact customer service.
Fault: Pump runs, there is no volume flow
1. There is no fluid.
Check the inlet, open all gate valves.
2. Inlet clogged.
Check the inlet and remove clogging.
3. Hydraulics jammed.
Clean the hydraulics.
4. Pipe system on the pressure side or pressure hose clogged.
Remove clogging and replace the damaged components if necessary.
5. Intermittent operation.
Check the switching system.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wilo Wilo-EMU FA + FK 17.1 and is the answer not in the manual?

Wilo Wilo-EMU FA + FK 17.1 Specifications

General IconGeneral
BrandWilo
ModelWilo-EMU FA + FK 17.1
CategoryWater Pump
LanguageEnglish

Related product manuals