18 Wilo SE 03/2017
en
Constant speed
Constant speed I II III:
Select the setting range of the constant speed.
Select speed stage I II or III.
The LED display shows the set speed c1, c2 or c3
according to the characteristic curve.
Completing the
setting
Do not rotate the operating button for 2 seconds.
LED display flashes 5 times and changes to the cur-
rent power consumption in W.
8 Decommissioning
Shutting down the
pump
Shut down the pump immediately in case of damage to
the connecting cable or other electrical components.
Disconnect the pump from the power supply.
Contact Wilo customer service or a specialist technician.
9 Maintenance
Cleaning Carefully remove soiling from the pump on a regular
basis using a dry duster.
Never use liquids or aggressive cleaning agents.
Pump Number of square metres of heated space in m²
Yonos PICO…/1-4 m - 80 120
Yonos PICO…/1-6 m 80 150 220
Yonos PICO…/1-8 m > 220
H+H-
NOTE
All settings and displays are retained if the power
supply is interrupted.