EasyManua.ls Logo

Windsor Chariot 3 iScrub 26 CSC26 - User Manual

Windsor Chariot 3 iScrub 26 CSC26
55 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
86395370-A 12/12/14
Chariot 3 iScrub 26
Scrubber
Operating instructions (ENG)
MODELS: CS26
10061500
CSC26
10061510
CSM26
10061580
CSCM26
10061590
CS26SP
10061520
CSC26SP
10061530
CSM26SP
10061600
CSCM26SP
10061610

Questions and Answers

  • S
    Selena LangAug 18, 2025
    How to troubleshoot no power on my Windsor Scrubber?
    • M
      Mary CowanAug 18, 2025
      If your Windsor Scrubber has no power, several things could be the cause. First, check all battery cable connections to ensure they are secure. The emergency shut-off may be activated, so try resetting it. Corroded battery cables can also prevent power, so clean the connections. Other potential issues include a faulty key switch (which would need replacing), the on-board charger being plugged in (unplug it and stow the cord), or a tripped main circuit breaker (reset it).
  • J
    Jessica CollinsAug 20, 2025
    What to do if my Windsor Scrubber has poor water pickup?
    • L
      Lori McintoshAug 20, 2025
      If your Windsor Scrubber isn't picking up water, start by checking the squeegee for any caught debris and remove it. Inspect the squeegee blades for wear; rotate or replace them if needed. A clogged vacuum hose can also cause this issue, so clear any obstructions. Ensure the vacuum hose is securely connected to both the squeegee and the recovery tank dome. Clean the recovery tank float system if it's dirty. Make sure the recovery tank is sealed properly by latching the lid and replacing any damaged gaskets. If the tank is full, the float-ball shut-off may be engaged, so empty the recovery tank. Finally, if foam is filling the recovery tank, empty it and consider using less or a different detergent, or add a defoamer.
  • D
    Donna SaundersAug 23, 2025
    Why does my Windsor Chariot 3 iScrub 26 CSC26 have little or no propel?
    • M
      Marcus GuerraAug 23, 2025
      If your Windsor Scrubber has little or no propel, there are several potential causes. Start by ensuring the battery is fully charged. If the machine was turned on with the pedal not in neutral, allow the pedal to return to neutral and restart the machine. Check for a tripped circuit breaker and reset it if necessary. If the wheels are spinning, decrease the brush pressure. If the controller has overheated, allow a cool down period. Inspect for a loose motor connection by checking the wires and connections from the controller to the motor. Also, check the wires and connections from the potentiometer resistance, as well as the wires, connections, and switch for both the drive reset circuit and platform circuit.
  • P
    Paul GibbsAug 26, 2025
    How to improve the scrubbing performance of my Windsor Scrubber?
    • P
      Pamela RodriguezAug 26, 2025
      If your Windsor Scrubber's scrubbing performance is poor, start by checking the scrub brushes for any caught debris and remove it. Replace worn brushes or pads. Note that using an improper detergent, brush, or pad can affect scrubbing performance, so contact equipment or application specialists. Also, ensure that the battery is fully charged.
  • R
    Robert TurnerAug 28, 2025
    What to do if there is little or no solution flow to the floor with my Windsor Scrubber?
    • C
      Christine ChanAug 28, 2025
      If your Windsor Scrubber has little or no solution flow to the floor, first check if the solution tank is empty and fill it if needed. Next, inspect the solution strainer for any clogs and clean it. Also, check the solution system plumbing for obstructions and clear them. Finally, the solution solenoid valve may be obstructed or faulty, so repair or replace it as necessary.
  • B
    Bridget ShepherdAug 30, 2025
    Why is the vacuum motor on my Windsor Chariot 3 iScrub 26 CSC26 Scrubber not running or running slowly?
    • A
      Antonio RiveraAug 30, 2025
      If the vacuum motor on your Windsor Scrubber doesn't run or runs slowly, inspect the vacuum circuit and switch, checking wires, connections, and the motor itself. Also, check the vacuum motor brushes for wear and replace them if needed, and inspect the commutator.
  • E
    ellisduaneSep 2, 2025
    What causes the brush motors on my Windsor Chariot 3 iScrub 26 CSC26 Scrubber to not run or run slowly?
    • K
      Kimberly OdonnellSep 2, 2025
      If the brush motors on your Windsor Scrubber do not run or run slowly, ensure the battery is charged. Check the wires, connections, and motor for any issues in the brush circuit or motor itself. Also, inspect the brush motor brushes for wear and replace them if necessary, checking the commutator as well.
  • S
    Shawn GriffinSep 4, 2025
    Why is the chemical metering system not operating on my Windsor Chariot 3 iScrub 26 CSC26 Scrubber?
    • M
      Manuel FloresSep 4, 2025
      If the chemical metering system on your Windsor Scrubber isn't working, start by checking if the chemical reservoir is empty and fill it if necessary. Inspect the chemical cap strainer for clogs and clean it. Clear any obstructions in the chemical system plumbing. If the flow meter is faulty, press the prime button; if chemical flows, repair or replace the flow meter. If the chemical pump is faulty, press the prime button; if chemical does not flow, repair or replace the pump.
  • D
    Debra KingSep 6, 2025
    What to do if the squeegee on my Windsor Chariot 3 iScrub 26 CSC26 Scrubber will not go up or down?
    • E
      Edward FullerSep 7, 2025
      If the squeegee on your Windsor Scrubber won't move up or down, check the wires, connectors, and actuator for any issues in the circuit or actuator itself. Also, inspect the cables and pulleys for faults and repair or replace them as needed.
  • M
    Mark YangSep 9, 2025
    Why does the scrub deck on my Windsor Scrubber go down, then raise?
    • D
      Daniel BoydSep 9, 2025
      If the scrub deck on your Windsor Scrubber goes down and then raises, check the wire connections and actuator for any faults in the actuator circuit or the actuator itself. Also, make sure brushes or pad drivers are installed on the machine.

Windsor Chariot 3 iScrub 26 CSC26 Specifications

General IconGeneral
Cleaning Path26 inches
Solution Tank Capacity29 gal / 110 L
Recovery Tank Capacity30 gal / 114 L
Power SourceBattery
Cleaning Path Width26 inches
Brush TypeDisk
Machine TypeWalk-Behind
Brush Motor Power0.75 hp
Voltage36V
Battery Voltage36V

Related product manuals