AN-301 SOS Button User Manual
23
6 Communication Format
Fport: 44.
The heartbeat and alarm are reported in normal data frame format. Here are frame
format definition for AN-301 as below
Bit
Byte
7
6-0
0
Sensor type(version) (Default value: 1)
1
Frame type (0: Heartbeat; 1: Data)
2
Alarm status (0: No alarm or getting answer for an alarm
report, 1: Alarm, 2: Alarm report delay)
3
Anti-dismantle status (0: Not dismantled; 1: dismantled)
4
Low voltage alarm status
(0: Normal voltage;
1: Low voltage)
voltage value ( the actual value
needs to be divided by 10, e.g.:
0x21 indicates 3.3V)
Figure: Frame Definition