EasyManua.ls Logo

WisyCom MPR50-IEM - Troubleshooting

WisyCom MPR50-IEM
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MPR50-IEM User Manual
Rev. 01

TROUBLESHOOTING
Problem
Possible cause
Possible solution
HW init failedmessage
appears on the display
Error during the hardware initialization
phase
-reset the receiver, if the
problem persists send to repair
at Wisycom Repair Centre
Battery Lowmessage
appears on the display
Low level on the battery
- change batteries or
- recharge the batteries
Battery charge failed
message appears on the
display
Error during batteries charger
(damage batteries or wrong batteries)
- change batteries
I2C communication error
message appears on the
display
Communication error on bus I2C
- send to repair at Wisycom
Repair Centre
Device ID copy1 invalid
Memory recovered
message appears on the
display
Error during the initialization phase. The
CRC-16 check of device data (copy 1)
detects error.
- nothing (the receiver
automatically replace the
corrupt copy1 with copy2)
Device ID copy2 invalid
Memory recovered
message appears on the
display
Error during the initialization phase. The
CRC-16 check of device data (copy 2)
detects error.
- nothing (the receiver
automatically replace the
corrupt copy2 with copy1)
RF copy1 invalid
Memory recovered
message appears on the
display
Error during the initialization phase. The
CRC-16 check of RF data (copy 1) detects
error.
- nothing (the receiver
automatically replace the
corrupt copy1 with copy2)
RF copy2 invalid
Memory recovered
message appears on the
display
Error during the initialization phase. The
CRC-16 check of RF data (copy 2) detects
error.
- nothing (the receiver
automatically replace the
corrupt copy2 with copy1)
The Serial Number of the
receiver in the Info menu
is UNCAL
Error during the initialization phase. The
CRC-16 check of device data (copy 1 and
copy 2) detects error.
- send to repair at Wisycom
Repair Centre
The errors 87 (Device ID
copy 1 ) and 88 (Device ID
copy 2) appear in the
errors list
Error during the initialization phase. The
CRC-16 check of device data (copy 1 and
copy 2) detects error.
- If the Serial Number in the
Info menu is UNCAL, then send
to repair at Wisycom Repair
Centre
- If the Serial Number in the
Info menu is not UNCAL,
continue to use the receiver
The errors 89 (RF mem.
copy 1 ) and 8A (RF meme.
copy 2) appear in the
errors list
Error during the initialization phase. The
CRC-16 check of RF data (copy 1 and copy
2) detects error.
- contact Wisycom for more
information
The receiver is not able to
tuned on the selected
frequency and the ON led
indicator remains red
Error during frequency tuning
- try to change the frequency, if
the problem persists send to
repair at Wisycom Repair
Centre

Related product manuals