91
User Manual WMF1500 S
Messages and instructions | Error messages and malfunctions
Error
number
Error
description
Action instructions
163 Flow error:
warm rinsing
Between each of the following steps switch off the coffee machine and on
again. If error not remedied carry out the next step.
Clean the brewing unit
w Care w Clean brewing unit, page 75
If error not remedied call WMFService
186 Steam boiler:
level
Beverage dispensing temporarily blocked.
Check that grounds container is correctly
inserted
Switch off the coffee machine and on again
188 Heater error Switch off the coffee machine, disconnect mains
plug
Call WMFService
189 Steam boiler:
heat-up time error
Switch off the coffee machine and on again
If error not remedied call WMFService
9083 Cooler
temperature is in
the frost range
Check whether the cooler temperature is set
toolow
9516
9517
Right grinder
blocked
Left grinder
blocked
Switch off the coffee machine
Disconnect mains plug
Remove bean hopper
Rotate the grinder disk counterclockwise only
by using the multitool for the hopper (two pins
must be inserted in the corresponding recesses
on the grinder; see illustration)
Replace hopper
Switch on the coffee machine
w Care w Bean hopper cleaning, page 82
If this occurs frequently:
Set grinding degree one stage coarser
w Other settings w Set grinding degree, page 60