Mixer:
Service date mixer: service message after 6.000 beverages.
The mixer counter can be read and reset.
Maintenance after 6,000 portionings mixer
Parts to be replaced:
• the mixer unit
• the mixer valve
Portioner:
Only grinder disk counter (no service message)
Only drive counter (no service message)
3.4 Temperature submenu
Setting range 80 to 100°C, default 96°C
Setting range 110 to 130°C, default 128°C
Changing the steam boiler temperature leads to great
changes in the dosage of milk and milk foam. Changes are
not recommended.
3.5 Submenu cleaning
Number of cleanings performed and to be performed
Number of mixer rinsings performed
Number of milk system cleanings performed
Time until request for cleaning/forced cleaning
Hardware for foamer rinsing available?
Delay in foamer rinsing after last beverage dispensing
Switch warning signal before foamer rinsing on/off