EasyManua.ls Logo

WMF 2000 S - Milk and Milk Foam Preparation

WMF 2000 S
33 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
WMF 2000S Service Manual edition 06/2012
WMF 2000S Service Manual
3.9 Submenu access control
The settings correspond to the default of the previous
standard setting. However, they can now be changed /
assigned independently of each other.
if „yes“ access to component test, service routines and counter.
if „yes“ customer check-up can be performed by the customer.
if „yes“ water filter can be exchanged and rinsed by the customer.
if „yes“ brewer can be exchanged by the customer
If activated (yes“), the key operator is able to
• do the descaling (turbo descaling)
• carry out and reset the customer check-up
• exchange and rinse the scale filter
• access the component test
• access the service routines
• access the counters
Maintenance messages in Key Operator mode
Customer check-up
Maintenance after 15,000 brewings
Tasks to be performed analogy to customer check-up,
brewer change, filter change
3.10 Submenu standards factoryservice/
customer
After tapping “self-detect” is first run automatically. All
components operating on 24 V or 30 V are automatically
addressed. The components are automatically identified.
During self-detect the grounds container must be in
place, the adjustable screen closed or the 24/30 V circuits
of the components are interrupted.
Reset with OK on display see
Service routines
Maintenance:
Customer check-up, brewer
exchange, filter change

Table of Contents