25
WMF 2000S Service Manual edition 06/2012
WMF 2000S Service Manual
Report
Display
Descr.
Entry ring mem.
Entry display
Comment
No. malfunction
memory
149 F149 General voltage
malfunction
√ √ If short circuit is present
in 24/30 V systems
86
157 Battery must be replaced √ √ Batterie voltage too low
to preserve data. Data is
automatically stored in
service memory.
161 F161 flowmeter
malfunction during
brewing
√ √ 241
162 F162 flowmeter
malfunction during
cleaning
√ √ 242
163 F163 flowmeter
malfunction during
checking
√ √ 243
164 F164 flowmeter
malfunction during hot
water dosage
√ √ 244
165 F165 flowmeter
malfunction during choc
dosage
√ √ 245
166 F166 flowmeter
malfunction during DK
feeding
√ √ 246
167 F167 flowmeter
malfunction during
descaling
√ √ 274
186 F186 timeout during
steam boiler filling
√ √ 247
187 F187 Steam boiler sensor
damage
√ √ 232
188 F188 Excess temperature
in steam boiler
√ √ 231

Table of Contents