WMF 2000S Service Manual edition 06/2012
WMF 2000S Service Manual
Report
Display
Descr.
Entry ring mem.
Entry display
Comment
No. malfunction
memory
9262 Auto detect malfunction:
Mixer not detected but
choc/topping portioner
detected
262
9263 Auto detect malfunction:
choc/topping portioner
not detected but mixer
detected
263
9264 Auto detect malfunction:
Mixer valve detected
but no powder portioner
detected or; Hot
water-Choc/topping
valve not detected but
choc/topping portioner
detected
264
9265 Auto detect malfunction:
Milk pump detected
but no cappuccino
valve detected or milk
pump not detected
but cappuccino valve
detected
265
9268 Power supply reports
voltage too low
External mains voltage! 268
9271 Pump switches to
pressure -lowering mode
(Info = button number)
Pump pressure lowered.
The beverage number is
entered into the laptop
Info column
271 Pump pressure
lowered, 9271
9275 Reset triggered by
customer
275 9275
9288 MDB communication
error coin checker
288 9288
9289 MDB communication
error card reader
289 9289
9290 MDB communication
error banknote reader
290 9290
9291 24 V are switched off and
then on again (reset for
MDB equipment on 24 V)
291 9291