45
3044826_201403
Service Manual
- Replace the upper and lower combustion chamber gasket;
lubricate the new gaskets with silicone grease.
- Lubricate the combustion chamber seat.
- Replace the monitoring electrode.
Check and replace the ignition electrode, if necessary.
Visual insulation check
replace, if broken