Installation Information
CSO24 and CSO30 (SWS #13508346)
2-3
#9001333 - Revision A - August, 2014
Electrical Requirements
NOTES:
Electrical supply for the convection steam oven must be placed in an adjacent cabinet within 3' (914 mm) of the
opening. Choose the electrical location shown in the illustrations on the following pages that best suits the instal-
lation.
Follow all National Electrical Code regulations. In addition as well as all local codes and ordinances when
installing electrical service.
Performance may be compromised if the electrical supply is less than 240 volts. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of operation.
Electrical Requirements
Electrical Supply 240/ 208 V AC, 60 Hz
Service 20 amp dedicated circuit
Receptacle NEMA 6-20R grounding-type
Power Cord 6' (1829)
To minimize shock hazard, the power cord must be plugged into a grounding-type receptacle, grounded to conform
with the National Electrical Code, ANSI/NFPA 70 latest edition, or Canadian Electrical Code (CSA) and all local
codes and ordinances. Refer to the illustrations below.
ELECTRICAL SHOCK HAZARD: PLUG INTO A GROUNDED 3-PRONG OUTLET. DO NOT REMOVE THE
GROUND PRONG. NO NOT USE AN ADAPTER. FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT
IN ELECTRICAL SHOCK, FIRE OR DEATH!
GROUNDED
NEMA RECEPTACLE
NEMA
PLUG
NEMA 6-20R Receptacle
3"
(76)
NEMA
PLUG
MINIMUM CORD
CLEARANCE
Power Cord Clearance