EasyManua.ls Logo

Worcester GREENSTAR 35 CDi - Page 44

Worcester GREENSTAR 35 CDi
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SERVICING AND SPARES
6 720 812 175 (2014/07)44
12. FAN ASSEMBLY
▶ Remove electrical connector from fan.
▶ Remove the siphon/condensate trap.
1. Undo the union connection (A) from the top of the gas valve.
▶ Remove wire clip (B) from air/gas adjustment assembly (C) then pull
gas pipe down.
2. Unscrew two screws (D).
3. Remove fan from boiler.
4. Remove three screws retaining the air/gas adjustment assembly (E).
▶ Reassemble with new fan assuring that seals are correctly fitted.
Fig. 77 Fan assembly removal
13. ELECTRODE ASSEMBLY
▶ Disconnect spark electrodes and flame sensor connection.
▶ Remove two screws (F).
▶ Remove spark/flame electrode assembly (G) from heat exchanger.
▶ Inspect the spark/flame electrode assembly and ceramics for signs of
contamination or damage, replace as necessary.
▶ If necessary, clean the spark/flame electrode assembly with a plastic
scouring pad.
▶ Replace electrode gasket.
▶ Re-assemble with the new gasket and secure with the screws (F)
removed earlier.
Fig. 78 Electrode assembly
14. AIR/GAS MANIFOLD
1. Remove cover panel (A) by removing screws (B).
▶ Check that the boiler is completely isolated from the gas supply.
Fig. 79 Top panel
2. Remove clips (C) and unscrew the two bolts (D).
▶ Unscrew and remove the two hexagon screws (E) securing the fan.
▶ Slacken fully the rear securing bolt (F).
NOTICE: Air/Gas ratio
▶ After re-assembly the combustion must be checked
using the procedure in the section “Setting the air/gas
ratio.”
▶ The setting of the gas ratio must be carried out by a
competent person.
Setting the air/gas ratio must not be attempted unless
the person carrying out the conversion is equipped
with a combustion analyser conforming to BS 7927
and is competent in its use.
B
C
A
D
2.
1.
E
3.
4.
6 720 812 176-25.1O
WARNING: Electrode gasket
▶ Do not remove the electrode assembly unless a new
gasket is available for re-assembly.
WARNING: Air/Gas manifold
▶ Do not remove the manifold unless a new gasket is
available for re-assembly.
13
G
F
6 720 812 175-20.1O
AB
6 720 812 175-15.1O
B
1.

Table of Contents