EasyManua.ls Logo

Worcester GREENSTAR UTILITY 32/50

Worcester GREENSTAR UTILITY 32/50
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VENTILATION INFORMATION
VENTILATION INFORMATION
BOILER LOCATION:
**The boiler can be installed under a worktop as long as:
The worktop above the boiler is easily removable for maintenance.
There is at least 10mm clearance above the boiler.
The front of the boiler is not enclosed.
VENTILATION:
Air vents must be functional at all times and the air supply must not be restricted or contaminated.
The boiler clearances must meet the minimum shown below for servicing and venting purposes.
* If this clearance is less than 75mm the flue 'knock-out' panel sections must be removed to improve air
circulation and cooling.
Do not place clothes or objects to hinder the air circulation required by the boiler.
ANNUAL
SERVICE CLEARANCES
600mm
300mm
10mm
10mm
720mm
1415mm
1312mm
10
GREENSTAR UTILITY 32/50 - 50/70
8 716 109 712b (07.2010)
GENERAL
INFORMATION
8 716 109 712b 07.10 12/7/10 12:28 Page 12

Other manuals for Worcester GREENSTAR UTILITY 32/50

Related product manuals