APPENDIX C: AIR SUPPLY PIPING
Use the Table below as a guide for sizing the airlines routed to your Gate Opener.
Recommended Pipe Size for Compressed Air Flow to 125 PSI
Air
Volume
Pipe Length feet (')
Nominal Pipe Diameter inches (")
CFM
25'
50'
75'
100'
150'
200'
300'
500'
1000'
6
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
3/4"
3/4"
18
1/2"
1/2"
1/2"
3/4"
3/4"
3/4"
3/4"
1"
1"
30
3/4"
3/4"
3/4"
3/4"
1"
1"
1"
1-1/4"
1-1/4"
45
3/4"
3/4"
1"
1"
1"
1"
1-1/4"
1-1/4"
1-1/4"
60
3/4"
1"
1"
1"
1-1/4"
1-1/4"
1-1/4"
1-1/2
1-1/2"
90
1"
1"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/2"
1-1/2"
2"
120
1"
1-1/4"
1-1/4"
1-1/4"
1-1/2"
1-1/2"
1-1/2"
2"
2"
150
1-1/4"
1-1/4"
1-1/4"
1-1/2"
1-1/2"
2"
2"
2"
2-1/2"
180
1-1/4"
1-1/2"
1-1/2"
1-1/2"
2"
2"
2"
2-1/2"
2-1/2"
240
1-1/4"
1-1/2"
1-1/2"
2"
2"
2"
2-1/2"
2-1/2"
3"
300
1-1/2"
2"
2"
2"
2"
2-1/2"
2-1/2"
3"
3"
360
1-1/2"
2"
2"
2"
2-1/2"
2-1/2"
2-1/2"
3"
3"