Symptom Possible causes Solution
Machine does not start
when the switch is in”
I”position.
Power cord is not plugged in. Plug in power cord.
Socket is defective
.
Check or replace plug, socket, fuses.
GFCI is triggered. Press reset on GFCI plug.
Machine pressure is
not consistent.
Pump is faulty. Contact service center .
Air in line. Remove the nozzle, turn on the machine for a while and
install the nozzle back.
Water inlet adapter is clogged
or dirty.
Remove the adapter, rinse it with water and put is back.
The pressure of the
pump is not adequate
Water supply is Insufficient. Open water source completely.
Water supply is restricted. Check If the water hose kinks or leaks.
Diameter of garden hose is too
small.
Replace with right garden hose .
Leak or kick in hose . Replace hose or untie kinks in hose.
No detergent Wrong nozzle is attached Attach the soap nozzle
Lance leaks O-ring needs to be replaced(See
Fig. A1) .
Replace o-ring .If the problem is not solved ,contact service
center to buy a new lance.