Chapter 1: Introduction and Installation 6 of 8
OPERATING ENVIRONMENT:
Ensure the operating Environment of the View-R meets these
requirements:
Temperature: 0° C to 50° C (32° F to 122° F)
Humidity: 8-90% relative humidity, non-condensing.
STORAGE ENVIRONMENT:
Temperature: -40° C to 60° C (-40° F to 140° F)
Humidity: 8-90% relative humidity, non-condensing.
INSTALLATION
For the LAN network, you MUST use a WTC DEP (Data Entry
Panel 105/300s/600) or the robot teach pendant on integrated
controls, to program a unique address in each WCU that will be
on the same LAN channel. If using a DEP, it must be connected
to the DEP port of the weld control. If you do not program a
unique LAN address in each WCU, communication errors will
result and the LAN channel will become disabled.
THE VIEW-R CONSOLE COMES INSTALLED WITH 2 USB ANTI-DUST
COVERS AND 2 MINI DISPLAY-PORT COVERS. THESE COVERS ARE
NOT INTENDED FOR A HIGH VIBRATION ENVIRONMENT AND MAY
BECOME LOOSE.
AS PART OF YOUR REGULAR MAINTENANCE ACTIVITIES CHECK
EVERY SIX MONTHS TO ENSURE THAT THE POWER SUPPLY CORD,
ETHERNET CABLE(S) AND THE DUST COVERS ARE FULLY SEATED.
SETTING WELD CONTROL UNIT’S NETWORK ADDRESSE(S):
THE ETHERNET NETWORK ADDRESS IDENTIFIES EACH WELD
CONTROL'S LOCATION ON THE NETWORK. EACH WELD CONTROL
MUST BE PROGRAMMED A UNIQUE ADDRESS BEFORE
COMMUNICATIONS WITH THE VIEW-R OVER THE ETHERNET ARE
POSSIBLE.