General accessories
Model
Order no.
Adapter cable
for connection to a recorder via analog output
AK 323 902 835
Interface cable
for connection of the LF 330/340 to a printer
via RS 232 interface
AK 325/S 902 837
Interface cable
for connection of the LF 330/340 to a PC
via RS 232 interface, incl. adaptor 9/25 pin and
operation manual for current terminal programs
AK 340/B 902 841
Communication set
consisting of Interface cable AK 340/B, with adaptor 9/25 pin
and transmission software Multi/ACHAT II
KOM 340 902 851
Telesco
1.5 - 3 m with sensor holder for conductivity cell
TetraCon
®
325-...
TH 340 402 802
Probe holder
for holding of TetraCon
®
325-...
SH 340 402 800
Protection armouring
Shock absorbent, rubber elastic, with stand and clamping
holder for sensor cable
SM 325 902 818
Beaker set
for protection armoring SM 325, consisting of one sensor
beaker LF, holding device and carrying strap for field
application
TG/Oxi-LF 902 812
Field armouring
extremely robust and shock-proof because of rubber elastic
protection armoring, with integrated sensor beaker for LF,
carrying handle, carrying strap, including holding device and
stand for measurements in the laboratory
FM 325/
Oxi-LF
902 813
Accessories for Conductivity measurement
Model Order no.
4-electrode conductivity measuring cell with
integrated temperature sensor (K=0.475 cm
-1
),
with watertight plug (IP 67),
with cable length 1.5 m
3 m
6 m
10 m
15 m
20 m
TetraCon
®
325
TetraCon
®
325-3
TetraCon
®
325-6
TetraCon
®
325-10
TetraCon
®
325-15
TetraCon
®
325-20
301 960
301 970
301 971
301 972
301 973
301 974
Ultrapure water measuring cell (K = 0,1 cm
-1
)
with integrated temp. sensor
LR 325/01 301 961
Trace conductivity measuring cell (K = 1 cm
-1
)
for ion exchanger + boiler feed water
LR 325/001 301 962
Glass/platinum 4-electrode measuring cell for
highly aggressive solutions
TetraCon
®
325/Pt 301 964
4 electrode measuring cell for pastes and
emulsions
TetraCon
®
325/S 301 602
Flow-through measuring cell TetraCon
®
DU/T 301 252
Connection cable for TetraCon
®
DU/T KKDU 325 301 963
Plastic armoring with hood for measuring cells
with up to 20 m cable length
A 325/K 903 830
Steel armoring with steel protection hood made
from VA 1.4571 (e. g. for strong and heavy flow)
for measuring cells with up to 20 m cable length
A 325/S 903 831
Control standard
6 bottles of control standard (KCI 0.01 mol/l) for
determination or check of the cell constant
E/SET 300 572