EasyManuals Logo

x-sense XP01 User Manual

x-sense XP01
11 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
05 06
MOISTURE. DO NOT KNOCK OR DROP THE ALARM. DO NOT OPEN OR TAMPER WITH THE ALARM
AS THIS COULD CAUSE MALFUNCTION.
Test & Silence Button
The Test & Silence button is used to test the units electronics and to silence the unit during an alarm.
When testing the alarm weekly, press the test button until you hear a short beep, indicating that the
alarm has entered the test mode.
Note: After a test has begun, the alarm will sound and the LED will  ash red. This does not
indicate that smoke/CO is present.
If you press the test button during an alarm state, the unit will enter the silence mode.
CO silence mode: Press the test button during an alarm state, the unit will enter the silence mode. If
the CO density still exceeds the alarm threshold within 6 minutes, the unit will enter another alarm state.
Otherwise, the unit will exit from silence mode after 9 minutes.
Note: If the smoke or CO concentration has reached an alarm level, silence mode cannot be
enabled. This unit will continue to alarm until the smoke or CO concentration has decreased
to a low level.
Alarm Sounder
The alarm will sound when there is smoke or CO present, when testing the alarm, and when there is a
fault.
LED Indicator
The LED indicator will fl ash in conjunction with the alarm sounder. Therefore, it will fl ash during the
following states: when powering on, in standby mode, during smoke or CO alarm states, when exiting
an alarm state, during test mode, when there is low battery, in silence mode, when there is a fault and
when the unit is at the end of its life.
Low Battery
The LED indicator will fl ash yellow together with one beep every 60 seconds.
(If you press the test button when there is low battery, the low battery signal will temporarily cease
for 10 hours; if you press the test button again, the unit will enter the test mode and then the standby
mode.)
End of Life
Once the maximum lifetime (10 years) is reached, the alarm delivers 2 beeps and the LED indicator will
ash yellow twice every 30 seconds . This end-of-life signal can be temporarily silenced for 3 days by
pressing the test button.
The end-of-life silence feature can only be used for a total of 30 days. After 30 days, the end-of-life signal
cannot be silenced.
LED Indicator
(red/green/yellow)
Test & Silence Button
Alarm Sounder

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the x-sense XP01 and is the answer not in the manual?

x-sense XP01 Specifications

General IconGeneral
Brandx-sense
ModelXP01
CategorySmoke Alarm
LanguageEnglish

Related product manuals