48 Freedom SW 3000 Owner’s Guide
Troubleshooting
4. If your Freedom SW 3000 or SCP is not displaying a Fault light, check
the following list to make sure that the present state of the installation
allows proper operation of the unit:
Is the inverter/charger located in a clean, dry, adequately ventilated
place?
Have the AC input breakers opened? If so, your pass through load may
have exceeded the rating of one or more of the input breakers.
Are the battery cables adequately sized and short enough?
Is the battery in good condition and are all DC connections tight?
Are the AC input and output connections and wiring in good
condition?
Are the configuration settings correct for your particular installation?
Are the display panel and the communications cable properly
connected and undamaged?
Is the battery temperature sensor and its cable properly connected and
undamaged?
5. Contact Xantrex Customer Service for further assistance. Please be
prepared to describe details of your system installation and provide the
model and serial number of the unit. See “Contact Information” on
page v for contact information.

Table of Contents

Other manuals for Xantrex FREEDOM SW 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xantrex FREEDOM SW 3000 and is the answer not in the manual?

Xantrex FREEDOM SW 3000 Specifications

General IconGeneral
BrandXantrex
ModelFREEDOM SW 3000
CategoryInverter
LanguageEnglish

Related product manuals