Operating in Battery Mode
975-0787-01-01 57
Power Save Timer
The Power Save Timer is an adjustable countdown timer from 1 to
25 hours (25hours is the default) that automatically shuts down
inverter operation to reduce battery discharge and preserve
battery life. During continuous inverter operation, the countdown
is initiated when power from the AC load drops to less than
approximately 50 watts and remains below this level. After
reaching the end of the countdown timer the inverter automatically
shuts down.
To change the countdown timer, see Settings on page 52.
Power Save Mode
By enabling the power save mode, the inverter can automatically
go to load sense mode by sending short pulses to further reduce
the battery discharge. Power save mode ends when a load greater
than 25W is connected.