SPECIFICATIONS
Power to Link 2000
Power Supply Voltage 9–40 volts DC (not for use with 32 V systems)
Power Supply Current 28 mA (typical; backlight adds 1 to 18 mA )
Measurements
Voltage Range 8.5–50 volts DC
Voltage Resolution 0.05 volts DC
Voltage Accuracy
+ 0.10 volts DC at full scale.
Current Range
+ 500 amps DC
Current Resolution 0.1 amp DC (from 0 to
+ 42.0 amps)
1 amp DC (from
+ 42 to + 500 amps)
Current Accuracy
+ 0.1 amp DC at full scale low range
+ 1 amp DC at full scale high range
Current Shunt
+ 0.25% ratio 50 mV @ 500 amps
Amp Hour Range
+ 9,999 amp hours
Amp Hour Accuracy
~ Time of Measurement x Current Error
Time Remaining Range 255 hours maximum
Charger Voltage Regulation
+ 0.2 volts DC
Cut out size: 4.75" x 2.75"
Panel size: 5.75" x 3.75"
Weight: Meter 9 oz.; Shunt 20 oz.