What to do if the LCD is off on my Xantrex SOLAR CHARGE 30?
J
Jason KingAug 5, 2025
If the LCD on your Xantrex Controller is off, there could be several reasons. First, ensure there's a proper connection to the battery and check the fuse on the battery cable. If the battery voltage is below 8.5V, charge it as soon as possible to exceed this level. Also, verify that the solar panel receives sufficient sunlight to generate voltage higher than the battery voltage. Finally, confirm that the PV cables are correctly connected to the solar panels and the charge controller, ensuring matching polarity.
W
Wendy GoodmanAug 11, 2025
Why does my Xantrex SOLAR CHARGE 30 show an over-voltage event?
K
Kevin McbrideAug 12, 2025
If your Xantrex Controller indicates an over-voltage event, verify that the battery voltage isn't surpassing the over-voltage disconnect point. If it is, disconnect the PV.
A
Ana BartonAug 20, 2025
How to fix battery charging voltage outside of range on Xantrex SOLAR CHARGE 30?
H
Heather TorresAug 20, 2025
If your Xantrex Controller displays a battery charging voltage outside of the normal range, verify that the actual battery type aligns with the charge controller's battery type setting for charging voltage. If they are incompatible, modify the battery type setting to correspond with the actual battery type.
R
Ryan BrownAug 28, 2025
What to do if Xantrex SOLAR CHARGE 30 Controller shows battery is discharged?
L
Lisa RogersAug 28, 2025
If the battery is discharged according to your Xantrex Controller, charge the battery as soon as possible.
Provides critical safety warnings for electrical shock, fire, and equipment damage, emphasizing qualified personnel and proper wiring during installation.