Do you have a question about the Xantrex Link 2000 and is the answer not in the manual?
Display | LCD |
---|---|
Communication | RS-232 |
Battery Voltage Measurement | Yes |
Current Measurement | Yes |
Amp-Hour Counting | Yes |
Temperature Compensation | Yes |
Amperage | 100 A |
Battery Type | AGM |
Operating Temperature Range | -20 to 60 °C |
Foundational knowledge about battery operation and capacity.
How to choose between Battery #1 and Battery #2 for monitoring.
Displays the voltage of the selected battery.
Shows current flow into or out of the selected battery.
Tracks amp hours consumed or replenished.
Estimates remaining operational time based on battery charge.
Enables or disables the inverter output.
Enables or disables the battery charger function.
Indicates presence of AC power.
Indicates charger status (Charge, Equalize).
Indicates charger status (Acceptance mode).
Indicates charger status (Float mode).
Lists default settings for various parameters.
Sets the load sensitivity threshold for inverter activation.
Manages AC current limits to prevent overloading sources.
Choose which battery to configure.
Sets the voltage threshold for considering a battery full.
Sets the current threshold for considering a battery full.
Sets the battery's capacity for accurate calculations.
Configures averaging period for time remaining estimates.
Selects battery chemistry (Liquid, Gel, AGM).
Sets or views the ambient temperature for compensation.
Switches amp-hour display to kilowatt-hour.
Activates settings for alternative energy systems.
Allows manual setting of Charge Efficiency Factor.
Adjusts capacity compensation for temperature.
Sets the Peukert's exponent for capacity calculations.
Changes Ahrs display to percentage remaining.
Sets current limit for alternators (Link 2000-R only).
Determines if Battery #2 is used for charger control.
Adjusts the display backlighting intensity.
Sets the discharge floor for battery time remaining.
Enables/disables active temp compensation.
Function for diagnostic purposes only.
Displays the Charging Efficiency Factor.
Shows the number of charge/discharge cycles recorded.
Shows the deepest discharge in amp hours.
Shows the running average of all discharges.
Guidance on recharging batteries based on capacity usage.
Strategy for managing two battery banks.
Explanation of overcharge amp hours accumulation.
Table showing capacity reduction at different discharge rates.
Table detailing charging states and voltages.
Lists default charging parameters.
How to identify full charge in multi-stage systems.
Identifying full charge in constant voltage systems.
Using specific gravity to determine battery charge level.
Methods to synchronize the Link 2000 with a charged battery.
Explains how charged parameters are used by the Link 2000.
Guidance on when to change charged parameters.
Overview of inverter and charger control functions.
Explains the meaning of status LEDs.
How to select batteries for display.
Overview of the monitoring parameters.
Displays inverter shutdown counts.
Shows the current software revision number.
Performs a display test of all LEDs and segments.
Resets all settings to factory defaults.
Presents the formula for calculating battery capacity using Peukert's equation.
Peukert's exponents for Prevailer and SeaGel batteries.
Peukert's exponents for Trojan batteries.
Peukert's exponents for Surrette and Rolls batteries.
Example of calculating Peukert's exponent.
How to verify current measurement accuracy using a multimeter.
Steps to reset the microprocessor for troubleshooting.
Details on what the limited warranty includes.
Xantrex's actions for warranty claims (repair/replace).
Instructions for obtaining warranty service.
Exclusions from the limited warranty coverage.
General disclaimer about the product.
Legal exclusions from warranties.
Notes on intended use and limitations.
Policy for returning products for service.
Important general notes before wiring.
Specific notes for marine and RV installations.
Explains the function and connection of each wire.