Troubleshooting
5-6 975-0162-01-01
The battery
clamps of the
jump-start
cables measure
zero volts.
External fuse (250 A)
is blown.
Replace 250 A, 32 V fuse with same
type and ratings.
See “Replacing the External Fuse”
on page 4–6.
The light does
not turn on.
Light bulb has burnt
out.
Remove lens cover and replace bulb
with one of the same type and rating.
See “Replacing the Incandescent
Light” on page 4–5.
The AM radio
does not work
or buzzes
continuously
(XPower
Powerpack
400 R only).
The XPower
Powerpack AC outlets
are being used,
causing interference.
Turn off the AC outlets.
Table 5-1
Troubleshooting reference
Problem Possible Cause Solution