XE210C Hydraulic Excavator Operating and Maintenance Manual 92
You mustn’t undercut a high bank
Undercutting a high bank may lead to the collapse of edge or landslide, causing a severe casualty.
Dig with care
Accidentally cutting off underground electric cable or gas pipe may
lead to a explosion or fire, causing a severe casualty.
a) Before the excavation, check the position of electric cables, gas pipes
and water pipes.
b) Keep a legal min. distance with electric cables, gas pipes and water
pipes.
c) If optical fiber cable is cut off due to the accident, Don’t look at the
end of cable which otherwise may lead to serious wound in your eyes.
d) Please contact directly with local related department, ask them to
mark out the position of all the underground cables and pipes.