XE210C Hydraulic Excavator Operating and Maintenance Manual 94
c) Refilling method
1) Park the machine on even ground.
2) Lower the bucket on the ground.
3) Run the engine for 5 min. at low-speed idling speed without load.
4) Turn off the engine; withdraw the key from key switch.
Important: if the procedure of shutting the engine is not right, the turbocharger may be damaged.
5) Pull the safe locking lever to LOCK.
Attention: deal with fuel with prudence. Before adding the fuel, engine must be shut off. No
smoking when the fuel tank is refilled or when fuel system is working.
6) Check level meter of fuel or fuel meter on monitor, add new fuel if necessary.
Important: prevent any dirt, dust, water or other foreign things into fuel system.
7) To prevent from condensation, fuel tank should be refilled after the completion of operation everyday.
Be careful not to splash the fuel on machine or ground. While refilling, regulated capacity should not
be exceeded.
8) After the refill, replace the oil inlet cap on fuel tank to avoid losing or damage.
Hydraulic system
a) Recommended hydraulic brand and name List 1-12 brand and name list of hydraulic oil
Special hydraulic oil used for
Xugong excavator (32
#
)
Special hydraulic oil used for
Xugong excavator (46
#
)
Anti-abrasion hydraulic oil
b) Capacity of hydraulic oil tank
List 1-13 Capacity list of hydraulic oil tank
Engine oil
a) Recommended engine oil brand and name
List 1-14 Brand and name list of engine oil
Special hydraulic oil used for Xugong excavator