Page #185 background imageLoading...
Page #185 background image
183
Parameter
Function
Unit
Default
value
Range
Effective
Suitable mode
Reference
chapter
P7-07
Bus instruction
refresh cycle
1us
3000
1~65535
10
5.6.2.1
P7-08
Compensation
Threshold of
Position Deviation
-
0
0~0
10
5.6.2.1
P7-09
Compensation times
for Position
Deviation
-
0
0~0
10
5.6.2.1
P7-10
RS232 station no.
-
1
0~100
1|2|3|4|5|6|7|8|9|1
0
8.2
P7-11.0~1
RS232
baud rate
00
300
01
600
02
1200
03
2400
04
4800
05
9600
06
19200
07
38400
08
57600
09
115200
0A
192000
0B
256000
0C
288000
0D
384000
0E
512000
0F
576000
10
768000
11
1M
12
2M
13
3M
14
4M
15
5M
16
6M
baud
rate
06
0~16
1|2|3|4|5|6|7|8|9|1
0
8.2
P7-11.2
RS232 stop bit
02-bit
21 bit
Stop bit
2
0~2
1|2|3|4|5|6|7|8|9|1
0
8.2
P7-11.3
RS232 parity bit
0-no parity
1-odd parity
2-even parity
Parity
bit
2
0~2
1|2|3|4|5|6|7|8|9|1
0
8.2
P7-20
Return to zero
direction (bus)
-
1
-9999~9999
9
10
5.6.2.1
P7-21
Filtering time after
return to zero(bus)
ScanA
Cycle
400
1~65535
10
5.6.2.1