180
COS D50 D60
X0
This instruction performs the mathematical COS operation on the floating point value in S
(angle RAD). The result is stored in D.
D51 D50
D61 D60
Note: Before the instruction is executed, the data in parameter S must be floating number;
otherwise, the execution result will be wrong.
4-9-10 TAN [TAN]
1) Summary
TAN [TAN]
16 bits
-
32 bits
TAN
Execution
condition
Normally ON/OFF,
rising/falling edge
Suitable
Models
XD, XL
Hardware
requirement
-
Software
requirement
-
2) Operands
Operands
Function
Data Type
S
Soft element address need to do tan
32bit,BIN
D
Result address
32bit,BIN
3) Suitable soft components
Operands
Word soft elements
Bit soft elements
System
Constant
Module
System
D
F
D
T
D
C
D
D
X
D
Y
D
M
D
S
K/H
I
D
Q
D
X
Y
M
S
T
C
Dn.
m
S
D
*Notes: D includes D, HD; TD includes TD, HTD; CD includes CD, HCD, HSCD, HSD; DM
includes DM, DHM; DS includes DS, DHS. M includes M, HM, SM; S includes S, HS; T
includes T, HT; C includes C, HC.
Description
(D51,D50)RAD (D61,D60)COS
Binary Floating Binary Floating
RAD value (angle×π/180)
Assign the binary floating value
COS value
Binary Floating
tudonghoatoancau.com