EasyManua.ls Logo

Xinje XL Series - 3-11 [PLS], [PLF]

Xinje XL Series
456 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
70
The status of the coil is reversed after using ALT (ON changes to OFF, OFF changes to ON).
M0ALT
M0
Y0
M100
Y1
M0
3-11 [PLS] , [PLF]
For using PLS instruction: soft component Y and M will act during one scanning period after
the drive is ON.
For using PLF instruction: soft component Y and M will act during one scanning period after
the drive is OFF.
Mnemonic
Function
Format and Devices
PLS
(Rising
Pulse)
Turn on a scan
cycle when
Rising edge
Operand:
X,Y,M,HM,SM,S,HS,T,HT,C,HC,Dn.m
PLF
(Falling
Pulse)
Turn on a scan
cycle when
Falling edge
Operand:
X,Y,M,HM,SM,S,HS,T,HT,C,HC,Dn.m
LDP
M100
ALT
M0
LD
M0
OUT
Y0
LDI
M0
OUT
Y1
Statements
Program
Statements
Program
Mnemonic and Function
PLS Y0
PLF Y0
tudonghoatoancau.com

Table of Contents

Related product manuals