6 7
12V DC INPUT CUT OUT CUT IN
HIGH 11.3V 12.5V
MEDIUM 10.1V 11.4V
LOW 9.6V 10.9V
24V DC INPUT CUT OUT CUT IN
HIGH 24.6V 26V
MEDIUM 22.3V 23.7V
LOW 21.3V 22.7V
TEMPERATURE CONTROL
When your fridge is first connected to the DC power
input the appliance will automatically switch on
and the LCD control panel will display the current
cabinet temperature, Battery Protection and Cooling
Speed setting as well as the current input voltage.
+ The Temperature Controller provides the ability
to set the desired temperature level and display
the current cabinet temperature. The electronic
controller has been programmed to maintain an
average of the set temperature.
+ The compressor will start up when the internal
cabinet temperature increases 0.5 to 1.5 degrees
above the set temperature and will run until the
temperature is 0.5 to 1.5 degrees below the set
temperature.
BATTERY PROTECTION
SETTING
1. Fridge to automatically restart once input voltage
is reached and is to retain all original settings
prior to monitor being activated.
2. Audible beeping to be heard when monitor is
activated.

Related product manuals