LID LATCH OPERATION
The lid of the fridge has a lock feature to prevent the
lid being opened inadvertently during transit or when
being moved or at other times when you want to
ensure the lid remains securely closed.
+ Slide the latch to the left to lock the lid.
+ Slide the latch the right to unlock the lid.
REPLACING THE DC FUSE
+ Unscrew the plastic end cap of the DC plug.
+ Carefully remove the end cap and metal cap on
the end of the fuse.
+ Remove the defective fuse.
+ Insert the new fuse. Make sure it is the same type
and rating (15A).
+ Place the metal cap back onto the top of the fuse
and then screw the plastic end cap back on.
METAL CAP
PLASTIC END CAP
FUSE (15A)
DC PLUG BODY