WS000089A
1. Oil plug
Empty the oil
CAUTION: Compressed Gas Hazard
Air inside the chamber may cause parts or liquid to be propelled with force. Be careful
when opening. Allow the chamber to de-pressurize before removal of the plug.
1. Place the pump in a horizontal position and unscrew the oil plug.
If the pump has a hole with the markings "oil out" it is important that this hole is used
for drainage.
WS001760A
2. Place a container under the pump and turn the pump.
3.
Unscrew the other oil plug.
If this hole has the markings "oil in", raise the pump upright for a short period of time
during drainage in order to drain all the oil.