WS001761A
Fill with oil
The oil should be a medical white oil of paraffin type that fulfills FDA 172.878 (a) and
viscosity close to VG32. Examples of suitable oil types are the following:
Statoil MedicWay 32
BP Enerpar M 004
Shell Ondina 927
Shell Ondina X430
1. Replace the O-rings of the oil plugs.
2. Refit an oil plug in the hole that faces downwards or is marked "oil out", and tighten.
Tightening torque: 10-40 Nm (7.5-29.5 ft-lb)
3. Fill with oil through the hole on the opposite side or the hole marked "oil in".
If the hole is marked "oil in", slightly tilt the pump and lower it again in order to fill the
pump with the correct quantity.
Quantity: approximately 1.0 L (1.1 qt).
WS001762A
4. Refit the oil plug and tighten.
Tightening torque: 10-40 Nm (7.5-29.5 ft-lb).
6.4 Service the pump
Type of
maintenance
Purpose Inspection interval
Initial inspection A Xylem-authorized personnel checks the pump condition.
From the results, the personnel recommends the intervals
for the periodical inspection and overhaul for the
installation.
Within the first year of operation.
6 Maintenance
46 Flygt 3102 Installation, Operation, and Maintenance Manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xylem Flygt 3102 Series and is the answer not in the manual?

Xylem Flygt 3102 Series Specifications

General IconGeneral
BrandXylem
ModelFlygt 3102 Series
CategoryWater Pump
LanguageEnglish

Related product manuals