What to do if Xylem Flygt FGC 411 operation failed?
- AAndre PriceAug 10, 2025
If the Xylem Controller operation failed, retry the operation. If the problem persists, restart the controller.
What to do if Xylem Flygt FGC 411 operation failed?
If the Xylem Controller operation failed, retry the operation. If the problem persists, restart the controller.
What to do if Xylem Flygt FGC 411 failed to detect the USB drive?
If the Xylem Controller fails to detect the USB drive, remove the USB drive and then re-insert it.
What to do if Xylem Flygt FGC 411 operation timed out?
If the Xylem Controller operation timed out, retry the operation. If the issue persists, restart the controller.
Why has the Xylem Flygt FGC 411 failed backing up configuration to USB drive?
The Xylem Controller may fail to back up the configuration to the USB drive because the USB drive is defective. To resolve this, remove the USB drive, re-insert it, or replace it with a new one.
What to do if Xylem Controller shows 'No configuration found on USB drive'?
If the Xylem Controller indicates that no configuration is found on the USB drive, remove the USB drive and check the USB drive.
Product Type | Controller |
---|---|
Enclosure Rating | IP66 |
Communication | Modbus RTU |
Inputs | Analog and Digital Inputs |
Power Supply | 100-240V AC |
Operating Temperature | -20°C to +60°C |
Explains pump activation based on level sensors or switches and various control functions.
Covers the alarm function, monitoring station status and raising alarms.
Instructions for connecting pump cables to terminals and protective earth.
Details on connecting the contactor coil to the NO and COM terminals for each pump.
Instructions for connecting float switches according to the provided table, including general-purpose digital input.
Guidance on connecting passive or active level sensors to the controller terminals.
Wiring diagram and lead color guide for connecting the HMI to the controller.
Instructions for connecting incoming power cables for a 3-phase power supply.
Instructions for connecting incoming power cables for a single-phase power supply.
Guidance on initial power-up procedures for the controller, with or without a USB drive.
Step-by-step instructions for using the setup wizard for initial configuration.
Guide to adjusting alarm parameters like activation delay, deactivation delay, and control outputs.
Steps to configure motor protection parameters like full load current and overcurrent threshold.
Provides a table of common pumping station alarms and their probable causes.
Step-by-step guide for upgrading the controller's firmware using a USB drive.
Instructions for upgrading the Human-Machine Interface (HMI) firmware.
Procedure for saving the controller's configuration settings to a USB drive.
Steps to restore saved configuration settings from a USB drive to the controller.
Lists common controller messages and alarms with their remedies and probable causes.
Details the Alarms menu, listing active alarms, their status, and text messages.
Overview of the Settings menu, covering language, pump control, motor protection, alarms, and communication.