en - Translation of the original instructions
• Liquids not compatible with the pump construction materials
• Hazardous liquids (such as toxic, explosive, flammable, or corro-
sive liquids)
Material
casing/
impeller
200–250,
200–315,
250–315
• Potable liquids other than water (for example, wine or milk)
Examples of improper installation:
• Hazardous locations (such as explosive, or corrosive atmos-
pheres).
• Location where the air temperature is very high or there is poor
ventilation.
• Outdoor installations where there is no protection against rain or
freezing temperatures.
Standard
Standard
Standard
Cast Iron /
Stainless
Steel
Do not use this pump to handle flammable and/or explosive
liquids.
Standard
Standard
Standard
• Do not use this pump to handle liquids containing abrasive, solid,
or fibrous substances.
• Do not use the pump for flow rates beyond the specified flow
rates on the data plate.
Ductil Iron /
Stainless
Steel
Stainless
Steel / Stain-
less Steel
Contact the local sales and service representative in the following cas-
es:
• If the density and/or viscosity value of the pumped liquid exceeds
the value of water, such as water with glycol; as it may require a
more powerful motor.
• If the pumped liquid is chemically treated (for example softened,
deionized, demineralized etc.).
• Any situation that is different from the ones that is described and
relate to the nature of the liquid.
Unbalanced single mechanical seal acc. EN 12756, version K Dimen-
sions. See Table 10 .
See Figure 6 for an explanation of the description code for the pump
This flow chart shows the maximum working pressure depending on
the pump model and the temperature of the pumped liquid.
The nameplate is a metal label that is located on the bearing bracket.
The name plate lists key product specifications. For more information,
see Figure 7
The nameplate provides information regarding the impeller and casing
material, the mechanical seal and their materials. For more informa-
tion, see Figure 8 .
IMQ or TUV or IRAM or other marks (for electric pump only)
Unless otherwise specified, for products with a mark of electrical-relat-
ed safety approval, the approval refers exclusively to the electrical
pump.
• Dimensions according EN 733 and additional not standardized
extension sizes
• Volute casing pump with back pull out power end
• Single stage
• For horizontal assembly
Maximum pressure generated by the pump
Maximum operating pressure
• Radial split volute casing with radial discharge
• Replaceable wear ring
Liquid temperature intervals
• Closed radial impeller with wear rings on both
sides
Version
Standard
Optional
• Single mechanical seal acc. EN 12756
• Optional cartridge mechanical seal
-20°C (-4°F)
-10°C (14°F)
140°C (284°F)
90°C (194°F)
• Radial ball bearings of motor
• Grease lubrication
For special requirements, contact the Sales and Service Department.
See the sectional drawing Figure 9 .
11 - 22 30 - 37 45 - 75 90 – 160
The metallic parts of the pump that come in contact with water are
made of the following:
See the measuring surface sound pressure levels LpA in Table 11 .
e1631 Installation, Operation, and Maintenance Manual