7.2 Fault analysis and solution
Error
code
Error
name
Causes Solution
Err-2
Overvoltage
protection
The driver power input
voltage exceeds the
specified value.
The regenerative energy is
too large when the drive is
braked.
Drive failure (loop failure)
Use correct voltage
Increase the acceleration /
deceleration time, reduce
load or increase the value
of PA-28.
Replace a new drive
Err-5
Overcurrent
protection
Motor current line A+, A-,
B+, B- short circuit.
Drive failure (loop, fail parts).
Motor burned out.
Check if the motor current
line is short-circuited, and
if there is a burr on the line.
Connect the current lines
correctly.
Replace a new drive
Replace a new motor
Err-8
Motor phase
wiring
connection
wrong
protection
Motor current line A+, A-,
B+, B- line sequence error.
Motor current line A+, A-,
B+, B- short circuit.
Verify that the motor
current line is properly
connected as required.
Check if the motor current
line is shorted.
Err-4
Encoder
error
Encoder feedback interface
is loose, off-line,
disconnected, shorted.
The motor components are
damaged.
Drive failure.
Check that the encoder
feedback cable is correct
and connected reliably.
Replace a new motor
Replace a new drive.
Err-7
Tracking
tolerance
error
protection
Motor current line A+, A-,
B+, B- is not reliably
connected, or the line
sequence is wrong.
The load is too large, the
acceleration/deceleration
time is too short, or the
motor selection is not
suitable.
The motor has an
electromagnetic brake and
the electromagnetic brake is
not opened as required.
The motor has an
electromagnetic brake, but
Verify that the motor
current line is correctly and
reliably connected as
required.
Increase the value of PA-9
appropriately without
affecting the processing
requirements of the
equipment.
Properly extend the
acceleration and
deceleration time to
reduce the load and
reduce the speed.
Check that the motor