www.yankong.com MS-S3 V2.1 User Manual
22 03/06/2019
the closing and opening of
the brake is not controlled by
the S-OFF signal of the
drive.
electromagnetic brake
working circuit is correct.
Control the motor brake
via the S-OFF+, S-OFF-
signals that come with the
drive.
Err-1
Drive
memory
read error
The drive is powered off
before parameter save
completed.
The data in the drive
parameter save area is
damaged.
Drive failure.
Execute EE-dEF to restore
the factory defaults of the
drive and eliminate the
fault.
Execute EE-dEF to restore
the factory defaults of the
drive and eliminate the
fault.
Replace a new drive.